Contact us

Calibration or Measurement is the set of operations performed under specific conditions to ensure that an instrument being calibrated is in a state of compliance with its technical specifications. Calibration gives an assurance that an instrument is in a state of compliance with the requirements for its intended use in specific process application.If the measured data is not reliable, decision taken based on the same cannot be reliable.

Thermolab testing’s NABL accredited calibration services are designed to ensure reliable, precise and traceable measurement results as per the International protocol & the applicable specific criteria documents.

Services offered by Thermolab Testing:

A team of trained & dedicated professionals carry-out testing of process, laboratory & scientific equipment & rooms under Thermal Validation to evaluate some critical parameters like FO, FH, Fd, Lethality, Lag time, Uniformity, Mean Kinetic Temperature & Hot & Cold Spot as applicable.Thermolab performs Thermal Validation for a wide range of equipments & rooms & assure 100% reliable results.

Types of Rooms:

In-lab:
Thermolab boosts of a sophisticated NABL accredited lab, with a dedicated quality assurance department, customer service cell and data processing zone. Trained team of professionals carry out the in-lab Calibration with minimum turnaround time.
On-site :
Thermolab also offers on-site and in-process calibration services at your location, with proven industry- leading quality standards. Trained engineers will execute the job as per the standard with accuracy and consistency.

Thermolab performs calibrations with its sophisticated NABL accredited lab & a dedicated quality.

Mechanical

pressure-gauge
Pressure Gauge
Vernier-Caliper
Vernier Caliper
Ph-meter
PH Meter
weight-box
Weight Box
conductivity-meter
Conductivity Meter
calculator
Calculator
  • Pressure – Pressure Transmitter, Pressure Switch, Pressure Gauge, Magnehelic Gauge, Inclined Manometer, Compound Gauge, Pressure Chart Recorders, etc.
  • Vacuum – Vacuum Transmitter, Vacuum Switch, Vacuum Gauge, Vacuum Chart Recorder etc.
  • Dimension – Vernier caliper, Micrometer, Depth Gauge, Thickness Gauge, Scale, Measuring Tape, Steel Rules and Height Gauges etc.
  • Air Velocity – Hot Wire Anemometer, Vane Type Anemometer
  • Level meter – Digital Level Indicator, Analog Level Indicator etc.
  • Flow meter – Flow Meter
  • Time – Timer & Stop watch
  • Speed – RPM Indicator, RPM Meter, Tachometer etc.
  • PH – pH meters, pH sensors
  • Conductivity – Conductivity Meters, Conductivity Sensors
  • Sound – Sound Level Meter.
  • Weight – E2, M1, M2, F1 & F2 Class Weight Box

Thermal

PT100-Temperature-Sensor
PT100 Temperature Sensor
glass-thermometer
Glass Thermometer
Thermohygrometer
Thermohygrometer
  • Temperature – Temperature Gauges, Temperature Sensors, Temperature Transmitters, Temperature, Switches, Temperature Chart Recorders, Temperature Data Loggers or Scanners with Sensors, Glass Thermometers, Digital Thermometers, Max & Min Thermometers, Wet & Dry Hygrometers & Sling Psychrometers etc.
  • Relative Humidity – Relative Humidity transmitter, Relative Humidity switch, Relative Humidity gauge, Relative Humidity sensor, Relative Humidity indicator & Data
    Loggers etc.
  • Temperature & Relative Humidity – Temperature & RH Transmitters, Digital Thermo hygrometers, Analog Thermo hygrometers, Analog Thermohygro clocks, Temperature & RH Scanners & Data Loggers etc.
Electro-Technical

Multifunction Calibrators for mV/mA & Ohms, Digital Ammeters(AC/DC), Analog Ammeters(AC/DC), Digital Voltmeters (AC/DC), Analog Voltmeters (AC/DC), 3 & ½ & 4 & ½
Digital Multimeters, 3 & ½ & 4 & ½ Digital Clamp meters, Earth Resistance Testers & Meggers etc.

Calibration Standards:
Sr. No Name of Standard Equipment Range Accuracy Traceability
1 Dry Well Calibrator (Fluke) 50 to 650°C, ± 0.5°C National
2 Dry Well Calibrator (Fluke) -25 to 140°C, ± 0.1°C National
3 Handheld Reference Thermometer (Fluke) / – 0- 400 Ω, ± 0.004% of Rdg. +0.002 Ω National
4 Platinum Resistances Thermometer (Fluke) (– 196) to 420°C ± 0.05°C National
5 Stability Chamber 0 to 50°C & 0 to 100%RH ± 0.5°C & ± 2%RH National
6 Temperature & RH Transmitter 0 to 50°C & 0 to 100%RH ± 0.5°C & ± 1.5%RH National / International
7 Digital Test Gauge (Crystal) 0 –500 psi / 0 – 5000 psi ± 0.02 % F.S.For 0 – 20 % ;± 0.1 % Rdg. for 20 – 100 % F.S. National
8 Digital Test Gauge (Dwyer) 0 – (-760mmHg) ± 0.05 % F.S. National
9 Digital Calibrator 0 to 100mmWc & 0 to 600mmWc ± 1% F.S National
10 Conductivity Simulator 5kΩ to 2MΩ ± 1% F.S. National
11 RTD Calibrator -100°C to 400°C ± 1% F.S National
12 Tungsten Carbide slip gauge set   0.5 to 100mm with quantity of 88 nos 0 grade National
13 Tungsten Carbide slip gauge set   0.5 to 100mm with quantity of 88 nos 0 grade National
14 Universal Calibrator   ± 199.99 mV, 0 to 19.999 mA & 0 to 500 Ω, ± 0.06mV ± 0.006mA & 0.5 Ω National